An Experimental Investigation on Dynamic Performance of Interference-fit Composite Joints with Blind Bolt and High Lock Bolt

Jing-chao WEI, Xiang-ming CHEN, Tian-jiao QU

Abstract


The experimental investigation were conducted in order to study the dynamic strength of the mechanically fastened composite joints, involving interference-fit joints with blind bolt and sliding-fit joints with high lock bolt. The joint type of the specimens researched was single-bolt, double-lap, which was a standard test configuration in ASTM for composite joints. Experimental results showed that the fatigue performance of the blind bolted joint was better than that of the high-locking bolted joint. The fatigue life of the blind bolted joints was 10-100 times higher than that of the high-locking bolted joint under the same cyclic stress, and the limit fatigue strength of the blind bolted joints was over 50MPa higher than hat of the high-locking bolted joints.

Keywords


Dynamic strength, Blind bolt, High lock bolt, Interference-fit, Composites


DOI
10.12783/dtetr/amee2018/25300

Refbacks